Windsor CMPSR 10070080 User Manual

Page of 58
MAINTENANCE 
 CMPS  86290230  02/22/07 
 
5.  PUMP 
 
4-4  
 
ONLY QUALIFIED MAINTENANCE 
PERSONNEL ARE TO PERFORM THE 
FOLLOWING REPAIRS. 
 
SOLUTION PUMP REPLACEMENT 
1.  
Turn off all switches and unplug machine. 
2.  Tilt machine back so bottom is exposed. 
3.  Remove the 6 screws that fasten the frame 
to the solution tank.  
4.  Remove the solution hoses from the fittings 
on the pump. 
5.  Reverse process to install. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
6.  REGULATING UNLOADER 
 
 
ONLY QUALIFIED MAINTENANCE 
PERSONNEL ARE TO PERFORM THE 
FOLLOWING REPAIRS. 
 
UNLOADER REPLACEMENT 
1.  
 Turn off all switches and unplug machine. 
2.   Tilt machine back so bottom is exposed. 
3.   Remove the 6 screws that fasten the frame   
      to the solution tank.  
4.   Remove the solution hoses from the fittings     
      on the pump. 
5.   Remove the unloader. 
6.  Reverse process to install. 
 
PUMP REPLACEMENT KITS 
 
MOTOR ONLY 86290270 
PUMP HEAD ONLY 86290280 
 
CAM & BEARING KIT
86290330 
VALVE & O-RINGS KIT 
(BOTH SIDES) 
86290340 
PLUNGER & SEALS KIT 
86290350