WARNING:
 Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
CLEAN-UP OF BROKEN LAMPS
 (see warnings on page two of this manual)
UV lamps contain a small amount of mercury, like a typical fluorescent lamp. DO NOT touch any of the 
mercury with your bare hands.
While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass 
1. 
with your hands.
Then, vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all  
2. 
lamp material.
Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed 
3. 
garbage bag.
Check with your local waste management authority for local disposal or recycling requirements. 
4. 
According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into  
household waste.
Wash hands and remove and wash clothes for added safety measures.
5. 
For replacement parts, contact Field Controls at:
Phone: 1-252-522-3031           Fax: 1-252-522-0214
Email: sales@fieldcontrols.com
LAMP Replacement Part Number
46511200
TROUBLESHOOTING GUIDE
Check to make sure 120VAC power is available at the electrical outlet.
1. 
Do not wire the unit into the appliance fan circuit. This will cause premature ballast or lamp failure and 
2. 
void the warranty. For proper operation, the unit requires 120VAC at all times.
Pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that 
3. 
the safety switch is fully engaged.
If lamp does not light up, rotate ballast slightly clockwise or counterclockwise.
4. 
If lamp does not light up after rotating ballast, replace lamp.
5. 
If unit still does not light up after replacing lamp, replace unit.
6. 