FIELD CONTROLS 46511500 User Manual

Page of 8
page 5
WARNING:
 Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Do not handle the lamp with bare hands. Oils on your hands tend 
9. 
to reduce lamp intensity. Install lamp into ballast.(See Figure 6)
Wipe off the lamp glass with the supplied alcohol wipe. Then 
10. 
insert the lamp through the center hole of the mounting base.(See 
Figure 7) The power cord must be 90° to the viewport hole on the 
mounting base.
With the ballast pressed against the mounting base, rotate the 
11. 
ballast clockwise 90º.
Do not wire the unit into the appliance fan circuit. Premature 
12. 
failure of the ballast and lamp will occur. The warranty will be 
voided. Plug the power supply cord into a standard 120VAC 
electric outlet. Check lamp operation by looking through the 
viewport hole. NOTE: The viewport hole is made of glass and 
will not allow any UVC rays to pass through. A blue glow 
should be seen in the duct.
If blue glow is not seen, make sure the base is properly 
13. 
installed onto duct. There is a proving switch located on the 
base that needs to be seated properly onto the duct.  
 
Make sure when installing the base the plated washer on the  
switch is raised approximately 
3
16
". The proving switch must  
be fully engaged. (See Figure 8) 
With aluminum or foil tape, seal all joints and seams of the plenum near the mounting location to 
14. 
reduce any direct viewing of light.
Figure 6
Figure 7
Figure 8