UltraViolet Devices Air Disinfection User Manual

Page of 12
7
I
NSTALLATION OF
LIND 24-EVO-2PM
Figure 2 - LIND 24-EVO-2PM Installation
1.
Installation and all wiring should confirm to state and local electrical codes as well as the current National
Electrical Code (NEC). Installation must be able to support approximately 32 pounds.
2.
After fixture is mounted and wired, open louver panels by removing thumbscrews. Install lamps (packed 
separately), close panels and replace thumbscrews.
R
ECOMMENDED
O
PTIONS
1.
Zenith
TM
Ultraviolet Meter: Provides accurate Easy-To-Read Levels of Intensity that may be interpreted by 
anyone, not just engineers. Zenith’s
TM
design makes it insensitive to ambient lighting within the area being surveyed.
P
RECAUTIONS
Immediately following initial installation of the 
Hygeaire
®
fixture, the occupied area, of the room, should be surveyed
with the Zenith
TM
Ultraviolet Meter, to insure that the ultraviolet radiant exposure of personnel is within acceptable
limits. Thereafter this procedure should be repeated whenever any maintenance is performed, including lamp changes
or whenever maintenance or repairs are performed in the vicinity of the fixture. In addition, procedures should be
adopted to insure that the fixture is switched off whenever personnel are working above the 6-foot level. Personnel who
work in and around the treated area should be briefed on the benefits and the precautions to be observed.
If there are any doubts or questions about the safety or the effectiveness of the installation, or if a sensitive ultraviolet
meter is required, please contact the Factory.