Emerson Process Management 3422 User Manual

Page of 398
 300
What’s new In Mark III
Upgrading a Mark II to a Mark III
 Reference, Installation, and Operations Manual
June 2013
3-9000-743 Rev S
S
ENIOR
S
ONIC
™ 
FLOW
 
CHARACTERIZATION
 
CALCULATIONS
. The SeniorSonic™ Mark III meter 
calculates/estimates flow-characterization information such as symmetry, cross-flow, 
turbulence, profile factor and swirl angle.
I
MPROVED
 
VELOCITY
 
ESTIMATION
. The Mark III utilizes an improved algorithm for using chord 
proportion history to estimate the flow velocity in the event of a chord failure. (Applicable 
on SeniorSonic™ models 3400 and 3422 and JuniorSonic™
 
model 3420.)
12-P
OINT
 P
IECEWISE
-L
INEARIZATION
. The Mark III offers up to 12 points for piece-wise 
linearization whereas the Mark II offers 10 points.
T
WO
 
INDEPENDENT
 
FREQUENCY
 
OUTPUT
 
PAIRS
. The Mark III offers two independent frequency 
output pairs, a feature particularly useful in custody transfer applications. Each frequency 
pair is individually configurable and utilizes a separate ground so that each pair can be 
wired to a separate flow computer.
N
EW
 
FREQUENCY
 
CONTENT
 
OPTIONS
. The Mark III meter adds four new frequency content 
options (gas velocity, sound velocity, energy rate, and mass rate) to the standard options 
(actual or standard flow rate).
F
REQUENCY
 
BI
-
DIRECTIONAL
 
OPTION
. This new option allows a frequency pair to be configured 
so that the selected content is represented by the "A" channel when flowing in the forward 
direction and by the "B" channel when flowing in the reverse direction.
C
ONFIGURABLE
 "B"
CHANNEL
 
PHASE
. Each frequency pair "B" channel phase is individually 
configurable so that its phase (relative to the "A" channel) can be used to determine the 
flow direction.
B
ATCH
 
DATA
 
SMOOTHING
. The Mark III meter offers a method for "smoothing" batch data that 
is particularly useful for applications that rely on the frequency output signals.
T
WO
 
INDIVIDUALLY
 
CONFIGURABLE
 
DIGITAL
 
OUTPUTS
 
PER
 
FREQUENCY
 
PAIR
. Each frequency output 
pair has two associated, individually configurable digital outputs. Each digital output is 
individually configurable for content and logic polarity. A test mode is available for testing 
each digital output pair.
E
THERNET
 
CONNECTIVITY
. The Mark III meter adds an optional Ethernet port in addition to 
two RS-232/RS-485 serial ports. This allows for multi-user, network-based access over an 
intranet.
H
IGH
-
SPEED
 
SERIAL
 
COMMUNICATION
 
PORTS
. The Mark III supports independently selectable 
baud rates on each of its serial communication ports up through 115200 bits/sec.
F
ULL
-
DUPLEX
 
SERIAL
 
COMMUNICATION
. The two standard RS-232/RS-485 serial ports can be 
configured for either half-duplex or full-duplex operation. Full-duplex communication 
allows a highly reliable TCP/IP protocol to be used by Daniel MeterLink which provides full 
functionality as is available via the optional Ethernet connection, including log access and 
waveform viewing.
A
UTOMATIC
 
COMMUNICATION
-
PROTOCOL
 
DETECTION
. The Mark III meter automatically detects 
all supported communication protocols which simplifies communication set-up.
O
PERATING
 
SYSTEM
. The Mark III utilizes an enterprise-class, protected-mode Linux 
operating system for enhanced reliability and future upgradability.