Monessen Hearth DBX24C User Manual

Page of 36
33D4047
17
DFX & DBX Series Vent Free Fireplaces
FINAL INSTALLATION
W
ARNING
Do not operate the unit without the screen 
frame panel and canopy installed.
REMOVE SCREEN
1.  Remove bottom louver. Figure 17 
2.  
Removing  fireplace  screen  frame  panel  by  pushing 
screen frame panel up and out. Figure 17
NOTE: Fireplace screen must be removed to access log 
box and to install canopy.
FP2513
remove screen
Fireplace 
Screen
Louvre
FP513
Figure 17 - 
Remove Fireplace Screen Panel
Canopy
INSTALL CANOPY
1.  Push louvers up and out to remove top louver assem-
bly.
.  Align the black canopy with the holes in the top frame 
assembly. Figure 18
3.  Install the three (3) screws (in owner’s manual packag-
ing) which attach the canopy to the top frame assembly. 
Figure 18
4.  Tighten all screws. Make sure the canopy is level and 
secure. Install top louver assembly. 
FP2514
install canopy
Screws
Canopy
FP514
Figure 18 - 
Install Canopy