DFX & DBX Series Vent Free Fireplaces
LOG PLACEMENT
DBX24C LOG PLACEMENT
 
Install one-piece log on two burner pins. Figure 21
DFX32C LOG PLACEMENT
 
Figure 20 
1.  Install front right log (#1) on two pins on right side of 
burner.
.  Install  left  front  log  (#)  on  two  pins  on  left  side  of 
burner.
3.  Install back log (#3) on back of burner. 
4.  Install right middle log (#4) on two pins on burner. Rest 
right end of right middle log on the right front log.
5.  Install left middle log (#5) on two pins on burner. Rest 
left end of left middle log on left front log. 
Pins 
LG700
32VFSC logs
Pins 
Left Front 
Log #
Left Middle 
Log #5  
Right Front 
Log #1 
Right 
Middle 
Log #4
Rear Log 
#3  
Pins 
Pins 
LG700
Figure 20 - 
DFX32C Log Placement
LG701
24BDXC logs
One-piece Log
Burner 
Pin
Burner Pin
LG701
Figure 21 - 
24BDXC Log Placement
PLACE ROCk WOOL
DFX24C and DFX32C MODELS
After  installing  logs,  pull  apart  dime-size  pieces  of  rock 
wool. Sprinkle rock wool evenly over burner ports. Wash 
hands  after  installing  rock  wool. 
Itching may occur.
LG702
VFS DBX rockwool
Dime Sized 
Rockwool 
Pieces
Figure 22 - 
Place Rockwool DFX24C/DFX32C
W
ARNING
  Use only rock wool provided with log 
set.
  Do not add additional rock wool.
  Place rock wool on burner ports only.
  keep air gap between rear log and 
burner clean.