Monessen Hearth CFX24 User Manual

Page of 36
17
CFX Vent Free Fireplace System
20301726
CHECK GAS PRESSURE
1.  Check gas type. The gas supply must be the same as 
stated on the appliance’s rating decal. If the gas supply 
is different from the fireplace, STOP! Do not install the 
appliance. Contact your dealer immediately.
2.  To  ease  installation,  a  24"  (610  mm)  flex  line  with 
manual shut-off valve has been provided with on this 
appliance. Install and attach 1/2" gas line onto shut-off 
valve. 
3.  After completing gas line connection, purge air from 
gas line and test all gas joints from the gas meter to 
the fireplace for leaks. Use a solution of 50/50 water 
and soap solution or a gas sniffer. 
4.  To adjust flame height, turn HI/LO knob to HI to get 
maximum pressure to burner. Turn HI/LO knob to LO 
to get minimum pressure. 
5.  To check gas pressures at valve, turn captured screw 
counter clockwise 2 or 3 turns and then place tubing 
to pressure gauge over test point. Turn unit to high.  
Figure 15 After taking pressure reading, be sure and 
turn captured screw clockwise firmly to reseal. Do not 
over torque. Check test points for gas leaks.
FP1979
Millivolt gas valve
FP1979
Figure 15 - 
Gas Pressure Check at Gas Valve 
Pressure 
Test “IN”
Pressure 
Test “OUT”
HI/LO Knob
Pilot Adjustment Screw 
W
ARNING
Do not use open flame to 
check for gas leaks.