Monessen Hearth HDV500NV/PV User Manual

Page of 64
HDV Series Direct Vent Gas Fireplace
16
56D3048
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
2  4  6  8 10 12 14 16 18 20
eg: A
FP2248
sidewall vent graph
VeNtING INStAllAtIoN 
teRMINAtIoN CleARANCeS FoR BuIlDINGS WItH CoMBuStIBle  
AND NoNCoMBuStIBle exteRIoRS 
Figure 12 - 
Allowable Venting Chart 
HoW to uSe tHe VeNt GRAPH
The Vent Graph should be read in conjunction with the following 
vent installation instructions to determine the relationship between 
the vertical and horizontal dimensions of the vent system.
1.  Determine the height of the center of the horizontal vent pipe exit-
ing through the outer wall. Using this dimension on the Sidewall 
Vent Graph below, locate the point intersecting with the slanted 
graph line.
.  From the point of this intersection, draw a vertical line to the 
bottom of the graph.
3.  Select  the  indicated  dimension,  and  position  the  fireplace  in 
accordance with same.
  Example A: If the vertical dimension from the floor of the fireplace 
is 11' (3.4m) the horizontal run to the face of the outer wall must 
not exceed 14' (4.3m).
  Example B: If the vertical dimension from the floor of the unit is 
7' (2.14m), the horizontal run to the face of the outer wall must 
not exceed 8
Z\x' (2.6m).
Sidewall Vent Graph showing the relationship between vertical 
and horizontal dimensions for a Direct Vent flue system.
Figure 13 - 
Rear Wall Venting Graph
Dimensions in Feet
Horizontal Dimension From the Outside Face of the Wall 
to the Back of the Fireplace
V
ertical Dimension From the Floor of Unit to the Center of the 
Horizontal V
ent Pipe
V
G
Combustible = 
6" (152 mm)
Noncombustible =
2” (51 mm)
F
Combustible
6" (152 mm)
Noncombustible = 
2” (51 mm)
V
V
G
G = Combustible 24"(610 mm)
 
Noncombustible 18"(457 mm)
Combustible & 
Noncombustible
H = 24" (610 mm)
J =  20" (508 mm)
V
H
J
C = Maximum depth of 48" (1219 mm)
    for alcove location
D = Minimum width for back wall of
    alcove location
    Combustible - 38" (965 mm)
    Noncombustible - 24" (610 mm)
E = Clearance from corner in alcove 
    location
    Combustible - 6" (152 mm)
    Noncombustible - 2" (51 mm)
E
V
D
C
C
Inside Corner 
Alcove Location
Outside Corner 
Balcony with No Side Wall
Balcony with Perpendicular
Side Wall
FP1951
termination clearances
48Z\v"
Floor to 
Center