Monessen Hearth HDV500NV/PV User Manual

Page of 64
HDV Series Direct Vent Gas Fireplace
3
56D3048
APPRoVeD leAK teStING MetHoD 
You may check for gas leaks with the following 
methods only:
  •  Soap and water solution
  •  An approved leak testing spray
  •  Electronic sniffer
NOTE:  Remove  any  excessive  pipe 
compound  from  the  connections. 
Excessive pipe compound can set off 
electronic sniffers. 
1.  Depress and turn knob counterclockwise 
 
to pilot position. 
.  Depress fully and hold pilot gas knob. Depress piezo 
ignitor as many times as needed to ignite the pilot. 
Keep knob fully depressed for a few seconds. 
Release  and  check  that  pilot  continues  to 
burn. 
If the pilot does not stay lit, repeat steps 1 and . 
Figure 45 - 
Pilot Position 
Check for gas leaks in each of the following locations:
  •  Pipe from the gas supply line connection to the gas valve
  •  Burner connections  
•  Field made joints / gas shutoff valve 
  •  Pilot  
•  Factory made joints
  •  Each joint or connection 
•  All joints on valve and control body
lIGHtING PIlot FoR tHe FIRSt tIMe - MIllIVolt   
lIGHtING PIlot - MIllIVolt  
W
ARNING
If using a soap and water solution 
to  test  for  leaks,  Do  Not  spray 
solution onto control body.
DANG
e
R
Never check for gas leak 
with open flame!
PILOT
OF
   
   
 P
IL
O
    ON
FP1935
control knob pilot
oPeRAtING INStRuCtIoNS - MIllIVolt