Monessen Hearth HDV500NV/PV User Manual

Page of 64
HDV Series Direct Vent Gas Fireplace
34
56D3048
1.  Check gas type. The gas supply must be the same as 
stated on the appliance’s rating decal. If the gas supply 
is different from the fireplace, StoP! Do not install the 
appliance. Contact your dealer immediately.
.  To ease installation, a 4" (610 mm) flex line with manual 
shut-off valve has been provided with on this appliance. 
Install and attach 1/" gas line onto shut-off valve. 
3.  After  completing  gas  line  connection,  purge  air  from 
gas line and test all gas joints from the gas meter to the 
fireplace for leaks. Use a solution of 50/50 water and 
soap solution or a gas sniffer. 
4.  To check gas pressures at valve, turn captured screw 
counter clockwise  or 3 turns and then place tubing 
to  pressure  gauge  over  test  point.  Turn  unit  to  high.  
Figure 50. After taking pressure reading, be sure and 
turn captured screw clockwise firmly to reseal. Do not 
over torque. Check test points for gas leaks.
W
ARNING
Do  not  use  open  flame  to  check  for  gas 
leaks.
eleCtRICAl WIRING
This fireplace will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor. 
W
ARNING
electrical  connections  should  only 
be  performed  by  a  qualified,  licensed 
electrician. Main power must be off when 
connecting to main electrical power supply 
or  performing  service. All  wiring  shall  be 
in compliance with all local, city and state 
codes. the appliance, when installed, must 
be  electrically  grounded  in  accordance 
with local codes or in the absence of local 
codes,  with  the  National  electrical  Code 
ANSI/NFPA 70 (latest edition) and Canadian 
electrical Code, CSA C22.1.
CA
ut
Io
N
label all wires before disconnecting when 
servicing controls. Wiring errors can cause 
improper and dangerous operation.
Verify proper operation after servicing.
FP1909a
signature command valve
alternate view
8/08
Figure 50 - 
Signature Command Valve
Pressure Inlet
Pilot Adjustment 
Screw
Pressure Outlet
FP1909a
SIGNAtuRe CoMMAND - CHeCK GAS PReSSuRe and eleCtRICAl INStAllAtIoN