Monessen Hearth CR User Manual

Page of 52
12
42D0200
Designer Series Gas Fireplaces
oPTIoNaL ToP vENT INSTaLLaTIoN 
oPTIoNaL ToP vENT aPPLICaTIoN 
The appliance is shipped as a rear vent unit. If the installation 
layout requires the unit to be a top vent configuration the appli-
ance can be converted by following the steps below.
When removing and refitting the plates and adapter be sure the 
associated gaskets are undamaged and refitted as required.
1.  Remove the eight (8) screws securing the flue pipe adapter 
to the fireplace body. Figure 9 
2.  Set the flue pipe adapter aside, complete with the gasket. 
Do not damage the gaskets as the adapter and gasket must 
be refitted.
3.  Remove the eight (8) screws securing the flue pipe cover to 
the top of the intake box and remove the cover and gasket. 
Figure 9
4.  Remove eight (8) screws securing the flue pipe to the back 
of the intake box and remove the pipe and gasket. Figure 
10
5.  Replace flue pipe to top of firebox. Ensure the gasket is 
in place and undamaged.  Secure with eight (8) screws.  
Figure 11
6.  Place the flue pipe cover and gasket removed in step 3 
over the flue opening in bottom of the intake box.
7.  Refit the flue pipe adapter and gasket to the top of fire-
place. Secure the adapter with eight (8) screws removed 
in step 1.
w
a
RNING
after  conversion  to  top  vent 
configuration the 4" (102 mm) flue 
pipe should be concentric within 
the  6
B\,"  (175  mm)  outer  collar 
(within 1/4").
FP1991
remove screws
FP1992
remove flue pipe
FP1993
replace flue pipe
Screws
Screws
Screws
Flue Pipe
Flue Pipe 
Adapter
Flue Pipe
Flue Pipe
Adapter
FP1991
Figure 9 - 
Remove 16 Screws from Flue Pipe 
Adapter and Flue Pipe Cover
FP1992
Figure 10 - 
Remove Flue Pipe
Flue Pipe 
Cover
FP1993
Figure 11 - 
Attach Flue Pipe to Top Vent Coln-
figuration