Monessen Hearth CR User Manual

Page of 52
42D0200
Designer Series Gas Fireplaces
13
INSTaLLaTIoN PRECauTIoNS
NoTE: This appliance must be installed with a Monessen 
approved venting system only. 
Consult  local  building  codes  before  beginning  the 
installation.  The  installer  must  make  sure  to  select  the 
proper vent system for installation. Before installing vent 
kit, the installer must read this fireplace manual and vent 
kit instructions. 
Only a qualified installer/service person should install vent-
ing system. The installer must follow these safety rules:
  Wear gloves and safety glasses for protection.
  Use extreme caution when using ladders or when on 
rooftops.
  Be aware of electrical wiring locations in walls and 
ceilings.
The following actions will void the warranty on your vent-
ing system:
  Installation of any damaged venting component.
  Unauthorized modification of the venting system.
  Installation of any component part not manufactured 
or approved by MHSC.
  Installation  other  than  permitted  by  these  instruc-
tions. 
vENTING INSTaLLaTIoN 
vENTING INSTaLLaTIoN 
w
a
RNING
Read  all  instructions  completely  and 
thoroughly  before  attempting  installation. 
Failure  to  do  so  could  result  in  serious 
injury,  property  damage  or  loss  of  life. 
operation  of  improperly  installed  and 
maintained venting system could result in 
serious injury, property damage or loss of 
life.
N
o
TICE
Failure  to  follow  these  instructions 
will void the warranty.
**1"
*3"
FP2280
vent pipe clear
**1”
**1"
**1”
*3"
326M”
FP2280
w
a
RNING
horizontal  sections  of  this  vent  system 
require  a  minimum  of  3"  clearances  to 
combustibles at the top of the flue and 1" 
clearance  at  the  sides  and  bottom  until 
the  flue  penetrates  the  outside  wall.  

minimum 1" clearance all around the flue 
is acceptable at this point of penetration.
vertical sections of this vent system require 
a minimum of 1" clearance to combustibles 
on all sides of the pipe.  
vENTING CLEaRaNCES
w
a
RNING
This  fireplace  must  be  vented  to  the 
outside. The venting system must NEvER 
be attached to a chimney serving a separate 
solid  fuel  burning  appliance.  Each  gas 
appliance must use a separate vent system. 
do not use common vent systems.
Figure 12 - 
Combustible Clearances for Vent Pipe 
* A minimum of 3" clearance to the top is required along horizontal 
length until flue pipe penetrates outside wall. 
** A minimum 1" clearance to combustibles permitted all around 
flue at outside wall.