KHLDV Series Gas Fireplace
FIrepLace InStaLLatIon 
cHecK GaS type
Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install 
fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or con-
version kit.
InStaLLInG GaS pIpInG to FIrepLace / Burner SySteM LocatIon
InStaLLatIon IteMS neeDeD
Before installing fireplace and burner system, make sure you have the items listed below.
  External regulator (supplied by installer) 
  Piping (check local codes) 
  Sealant (resistant to propane/LP gas) 
  Test gauge connection* 
  Sediment trap (recommended)  
  Pipe wrench 
  Tee joint 
  Equipment shutoff valve* 
  Approved flexible gas line with gas connector (if allowed by local codes — not provided)
*  A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge 
connection. Purchase the CSA design-certified equipment shutoff valve from your dealer.
For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce 
incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do 
not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with 
the vent pointing down as shown in Figure 28. Pointing the vent down protects it from freezing rain or sleet. 
w
arn
In
G
a  qualified  installer  or  service  person 
must  connect  appliance  to  gas  supply. 
Follow all local codes. 
caut
Ion
For  propane/Lp  units,  never  connect 
fireplace directly to the propane/Lp supply. 
this  burner  system  requires  an  external 
regulator (not supplied). Install the external 
regulator between the burner system and 
propane/Lp supply.
FP1977
external regulator
Figure 28 - 
External Regulator with Vent Pointing Down 
(Propane/LP Only)
FP1977
External 
Regulator 
100 gallon (min) 
Propane/LP 
Supply Tank 
Vent Pointing 
Down
When  using  copper  of  flex  connectors  use  only  fittings 
approved  for  gas  connections.  The  gas  control  inlet  is 
3/8" NPT.
caut
Ion
use only new black iron or steel pipe. Internally 
tinned copper or copper tubing can be used 
per national Fuel code, section 2.6.3, providing 
gas meets hydrogen sulfide limits, and where 
permitted by local codes. Gas piping system 
must  be  sized  to  provide  minimum  inlet 
pressure (listed on data plate) at the maximum 
flow rate (Btu/hr). undue pressure loss will 
occur if the pipe is too small.