KHLDV Series Gas Fireplace
FP1979
Millivolt gas valve
MILLIVoLt - cHecKInG GaS preSSure and eLectrIcaL InStaLLatIon 
1.  Check gas type. The gas supply must be the same as 
stated on the appliance’s rating decal. If the gas supply 
is different from the fireplace, Stop! Do not install the 
appliance. Contact your dealer immediately.
2.  To ease installation, a 24" (610 mm) flex line with manual 
shut-off valve has been provided with on this appliance. 
Install and attach 3/8" gas line onto shut-off valve. 
3.  After  completing  gas  line  connection,  purge  air  from 
gas line and test all gas joints from the gas meter to the 
fireplace for leaks. Use a solution of 50/50 water and 
soap solution or a gas sniffer. 
4.  To  adjust  flame  height,  turn  HI/LO  knob  to  HI  to  get 
maximum pressure to burner. Turn HI/LO knob to LO 
to get minimum pressure. note: To make the process 
of checking the gas pressure easier, unfasten the two 
screws which secure the gas valve to the side of the 
firebox and bring forward. [Remove the glass to allow 
the valve to come forward. (Refer to Page 45 for glass 
removal.)] When done, you must refasten the gas valve 
into place. 
5.  To check gas pressures at valve, turn captured screw 
counter clockwise 2 or 3 turns and then place tubing 
to  pressure  gauge  over  test  point.  Turn  unit  to  high.  
Figure 30. After taking pressure reading, be sure and 
turn captured screw clockwise firmly to reseal. Do not 
over torque. Check test points for gas leaks.
Do not use open flame to check for 
gas leaks.
w
arn
In
G
Figure 30 - 
Gas Pressure Check at Gas Valve 
Pressure 
Test “IN”
Pressure 
Test “OUT”
HI/LO Knob
Pilot Adjustment 
Screw
eLectrIcaL wIrInG
This fireplace will work without any electrical supply. Elec-
tricity is only needed to operate the blower and the light 
located behind the logs inside the firebox.
note: If installed in mobile home, fireplace must be bolted 
securely to floor. 
w
arn
In
G
Verify proper operation after servicing. 
FP1979
electrical connections should only be performed by a qualified, licensed 
electrician.  Main  power  must  be  off  when  connecting  to  main  electrical 
power supply or performing service. all wiring shall be in compliance with 
all  local,  city,  and  state  codes.  the  appliance,  when  installed,  must  be 
electrically grounded in accordance with local codes, or in the absence of 
local codes, with the National Electrical Code ANSI/ NFPA 70 (latest edition) 
and Canadian Electrical Code, CSA C22.1.
Label all wires before disconnecting when servicing controls. wiring errors 
can cause improper and dangerous operation. 
caut