Monessen Hearth IDV490NVC User Manual

Page of 40
20 
57D0016
ON
OFF
PILOT
HI
LO
ON
OFF
TH
TP
TH/TP
ON
OFF
Optional 
15’ Wall Switch
ON
OFF
Optional 
Remote Control 
������
��������������
����������
�������
�������������
��������������
���������
�����
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a 
junction box at the desired location on the wall. See Figure 17.  
NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire 
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local 
code.
Figure 17 - Wiring Diagram for Wall Switch 
ELECTRICAL INSTALLATION 
ELECTRICAL WIRING
Electrical connections should only be performed by a qualified, licensed electrician. 
Main power must be off when connecting to main electrical power supply or performing 
service. All  wiring  shall  be  in  compliance  with  all  local,  city,  and  state  codes.  The 
appliance,  when  installed,  must  be  electrically  grounded  in  accordance  with  local 
codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 
70 (latest edition) 
and Canadian Electrical Code, CSA C22.1.
W
ARNING
Label all wires before disconnecting when servicing controls. Wiring errors can cause 
improper and dangerous operation. 
CAUTION
Verify proper operation after servicing. 
This insert will work without any electrical supply. Electricity is only needed to operate blower.