Monessen Hearth DFS42PVC User Manual

Page of 44
71D0532 
19
ELECTRICAL WIRING
The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO 
OPERATE.
CONNECTING OPTIONAL WALL SWITCH
  1.  Use 18 awg, two-wire cable, 15 feet maximum length.
  2.  At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to 
TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of 
the unit. The color of the wires does not matter. 
Figure 17 - Wiring Diagram
Optional Wall
Switch or Remote 
Receiver
Switch
On/Off
Switch
On/Off
Switch
Wall
Switch
ODS 
Pilot
  
Valve
 TH = 3
TP = 1
TP/TH = 2
ODS 
Pilot
Spade 
Terminal
Label all wires prior to disconnection 
when servicing controls. Wiring 
errors can cause improper and 
dangerous operation. Verify proper 
operation after servicing.
W
ARNING