OBSeRVeD PROBLeM
Piezo ignitor will not light the 
pilot after repeated pressing 
of piezo ignitor. 
Pilot will not stay lit. 
Burner  will  not  light  when 
valve and burner switch are 
both on.
Glass fogs up
Blue flames
Sooting 
POSSiBLe cAuSe
1.  Defective ignitor
.  Misaligned spark electrode 
1.  Defective thermocouple. 
Loose thermocouple
.   Air in gas line
3.  No gas
1.  Defective switch
.  Defective thermopile
3.  Thermostat set too low/defective 
1.  Normal condition 
1.  Normal during start up 
1.  Flame impingement 
ReMeDy
1.  Check connections to ignitor. Replace 
ignitor if ignitor connections are good, 
but there is no spark.
.  Check for spark arcing from the elec-
trode to pilot. Adjust and retighten. 
1.  Check for proper connection of ther-
mocouple to rear of valve. 
.  Bleed line. Contact dealer 
3.  Check shutoff valve and gas supply 
(LPG tank)
1.  Check  switch  connections.  Jump 
wires at switch. 
.  Check connections to valve. Contact 
dealer. 
3.  Turn  up  thermostat  to  start  unit. 
Check thermostat connections. 
1.  Allow appliance to warm up. Glass 
will clear. Additives in the gas may 
dirty glass. Clean glass when cool. 
1.  Flames  will  yellow  as  appliance 
heats up. 
1.  Check log position. Open shutters to 
increase primary air. 
NOTE: All troubleshooting items are listed in order of operation.