sidewall vent graph
hoW to uSe the VeNt GRAph
The  Vent  Graph  should  be  read  in  conjunction  with  the 
following  vent  installation  instructions  to  determine  the 
relationship between the vertical and horizontal dimensions 
of the vent system.
1.  Determine the height of the center of the horizontal vent 
pipe exiting through the outer wall. Using this dimension 
on the Sidewall Vent Graph, locate the point intersecting 
with the slanted graph line.
2.  From the point of this intersection, draw a vertical line 
to the bottom of the graph.
3.  Select the indicated dimension, and position the fire-
place in accordance with same.
  example: If the vertical dimension from the floor of the 
fireplace is 11' (3.4 m) the horizontal run to the face of 
the outer wall must not exceed 14' (4.3 m).
  example: If the vertical dimension from the floor of the 
unit is 7’ (2.14 m), the horizontal run to the face of the 
outer wall must not exceed 8Z\x' (2.6 m).
Sidewall  Vent  Graph  showing  the  relationship  between 
vertical and horizontal dimensions for a Direct Vent flue 
system.
Figure 13 - 
Rear Wall Venting Graph
Horizontal Dimension From the Outside Face of the Wall 
to the Back of the Fireplace
V
ertical Dimension From the Floor of Unit to the Center of the 
Horizontal V
ent Pipe
Dimensions in 
Feet
VeNtING INStALLAtIoN
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors. 
G =
Combustible 
  6" (152 mm)
Noncombustible 
  2" (51 mm)
F =
Combustible 
  6" (152 mm)
 
Noncombustible 
  2" (51 mm)
G
Balcony - 
with no side wall
M = 
Combustible &
Noncombustible
  12" (305 mm)
M
Balcony - 
with perpendicular side wall
M = 24" (610 mm)
P = 20” (508 mm)
M
F
Alcove Applications*
C
D
C
E
V
V
Combustible &
Noncombustible
V
V
V
E
 = Min. 6” (152 mm) for 
non-vinyl sidewalls
Min. 12” (305 mm) for
vinyl sidewalls
O
 = 8’ (2.4 m) Min.
O
P
Figure 12 - 
Allowable 
Venting 
584-15
 
No. 
  of Caps 
 
D
Min.
 
  C
Max.
 
3’ (914 mm)  2 x D
Actual
 
6’ (1.8 m) 
1 x D
Actual
 
9’ (2.7 m) 
2/3 x D
Actual
 
12’ (3.7 m) 
1/2 x D
Actual
D
Min.
 = # of Termination caps x 3
C
Max.
 = (2 / # termination caps) x D
Actual
*Note: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or 
non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a 
termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must 
be a minimum of 1’ (305 mm) below the termination cap.