Monessen Hearth LX32DV User Manual

Page of 48
51D0528
25
LX Series Direct Vent Gas Fireplace
checKING GAS pReSSuRe and eLectRIcAL INStALLAtIoN
1.  Check gas type. The gas supply must be the same as 
stated on the appliance’s rating decal. If the gas supply 
is different from the fireplace, Stop! Do not install the 
appliance. Contact your dealer immediately.
2.  To ease installation, a 30" (mm) flex line with manual 
shut-off valve has been provided with on this appli-
ance. Install and attach 1/2" gas line onto shut-off 
valve. 
3.  After completing gas line connection, purge air from 
gas line and test all gas joints from the gas meter 
to the fireplace for leaks. Use a solution of 50/40 
water and soap or a gas sniffer. 
4.  To adjust flame height, turn HI/LO knob to HI to get 
maximum pressure to burner. Turn HI/LO knob to 
LO to get minimum pressure. 
5.  To  check  gas  pressures  at  valve,  turn  captured 
screw counter clockwise 2 or 3 turns and then place 
tubing to pressure gauge over test point. Turn unit 
to high. Figure 35. After taking pressure reading, 
be sure and turn captured screw clockwise firmly 
to reseal. Do not over torque. Check test points for 
gas leaks.
FP1979
Millivolt gas valve
FP1979
Figure 35 - 
Gas Pressure Check at Gas Valve 
Pressure 
Test “IN”
Pressure 
Test “OUT”
HI/LO Knob
Pilot Adjustment Screw 
W
ARNING
Do  not  use  open  flame  to  check  for  gas 
leaks.
eLectRIcAL WIRING
This fireplace will work without any electrical supply. Elec-
tricity is only needed to operate blower.
Note: If installed in mobile home, fireplace must be bolted 
securely to floor. 
W
ARNING
electrical  connections  should  only 
be  performed  by  a  qualified,  licensed 
electrician. Main power must be off when 
connecting to main electrical power supply 
or  performing  service. All  wiring  shall  be 
in compliance with all local, city and state 
codes. the appliance, when installed, must 
be  electrically  grounded  in  accordance 
with local codes or in the absence of local 
codes,  with  the  National  electrical  code 
ANSI/NFpA 70 (latest edition) and canadian 
electrical code, cSA c22.1.
c
A
ut
Io
N
Label all wires before disconnecting when 
servicing controls. Wiring errors can cause 
improper and dangerous operation.
Verify proper operation after servicing.