Monessen Hearth LX32DV User Manual

Page of 48
51D0528
35
LX Series Direct Vent Gas Fireplace
opeRAtING INStRuctIoNS
AppRoVeD LeAK teStING MethoD 
You  may  check  for  gas  leaks  with  the  following 
methods only:
• 
Soap and water solution
•  
An approved leak testing spray
•  
Electronic sniffer
Note:  Remove  any  excessive  pipe 
compound  from  the  connections. 
excessive pipe compound can set off 
electronic sniffers. 
1.  Depress  and  turn  knob  counterclockwise 
  to 
pilot position. 
2.  Depress fully and hold pilot gas knob. Depress piezo 
ignitor as many times as needed to ignite the pilot. 
Keep  knob  fully  depressed  for  a  few  seconds. 
Release and check that pilot continues to burn. 
If the pilot does not stay lit, repeat steps 1 and 2. 
Figure 49 - 
Pilot Position 
Check for gas leaks in each of the following locations:
  Pipe from the gas supply line connection to the gas valve
•  
Burner connections  
  Field made joints / gas shutoff valve 
•  
Pilot  
  Factory made joints
•  
Each joint or connection 
  All joints on valve and control body
LIGhtING pILot FoR the FIRSt tIMe   
LIGhtING pILot
W
ARNING
If using a soap and water solution 
to  test  for  leaks,  Do  Not  spray 
solution onto control body.
DANG
e
R
Never check for gas leak 
with open flame!
PILOT
OF
   
   
 P
IL
O
    ON
FP1935
control knob pilot