51D0528
LX Series Direct Vent Gas Fireplace
opeRAtING INStRuctIoNS
OF
F
PILO
T
ON
PILOT
FP1937
control knob on
MAIN BuRNeR SWItch
 
The “ON/OFF/RS” switch for the main burner can be found behind door of the 
fireplace. This switch allows you to turn on and to turn off the main burner without 
using the gas valve knob. Make sure the button is in the “ON” position to light 
the main burner. Figure 50
LIGhtING the BuRNeR
Depress and turn the knob counterclockwise 
 to the “ON” position. Figure 
51. It will take less than four (4) seconds for the burner to ignite. 
pILot poSItIoN
Depress and turn knob to pilot position to keep burner off while maintaining the 
pilot light. Figure 52
Depress and turn knob clockwise 
 to “OFF” position. Figure 53
to tuRN oFF GAS
Figure 52 - 
Pilot Position 
LIGhtING BuRNeR   
PILOT
OF
F
PILOT
O
N
PILOT
OF
   
   
 P
IL
O
    ON
FP1935
control knob pilot
OFF
ON
RS
Figure 53 - 
Off Position 
W
ARNING
the  control  is  fitted  with  a  safety  interlock 
device which prevents unsafe ignition of the 
pilot burner after the control knob has been 
turned  to  the  oFF  position.  the  knob  may 
only  be  rotated  back  to  the  pILot  position 
after  the  safety  magnet  has  been  released 
(approximately 60 seconds). you will hear a 
“click” when the safety magnet releases. 
Figure 51 - 
On Position 
Figure 50 - 
On/Off/RS Switch