Monessen Hearth LX32DV User Manual

Page of 48
38
51D0528
LX Series Direct Vent Gas Fireplace
  Never operate fireplace if glass is broken.
  Replace any glass that is chipped, cracked, or broken. 
Replacement glass assemblies MUST be supplied by 
fireplace manufacturer — No substitute materials may 
be used.
cLeANING 
and
 MAINteNANce 
c
A
ut
Io
N
Always use gloves when handling broken 
glass.
W
ARNING
Make sure the glass panel edges do not 
touch  any  metal  parts  during  thermal 
expansion.
FP2722
Lx blower
BLoWeR
FP2722
White
(Hi Temp)
OFF
Variable
Fan Control
ON
White
(Hi Temp)
Fan Limit
Switch
(N.O.)
White
(Hi Temp)
Blower
Motor
Black
White
Green
110/115 V.A.C
Blower Plug
FP2723
blower wiring
WIRING DIAGRAM FoR BLoWeR