LX Series Direct Vent Gas Fireplace
cLeARANceS
cLeARANceS to coMBuStIBLeS 
Follow these instructions carefully to ensure safe installation. Failure to 
follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other combustible 
material other than wood flooring. If installed on carpet or vinyl flooring, the 
appliance shall be installed on a metal, wood or noncombustible material 
panel extending full width and depth of the appliance.
W
ARNING
12” (305 mm)
Max. Depth
9” (229 mm)
Minimum
LX32 - 39” (991 mm)
LX36 - 43” (1092 mm
)
LX32 - 30” (762 mm)
LX36 - 34” (864 mm)
6” 
(152 mm)
12” (305 mm)
Minimum
466M”
(1187 mm)
446M”
(1137 mm)
FP2711
combustible clearances
Side Wall
Ceiling
Combustible 
Mantel
Noncombus-
tible Facing
FP2711
Figure 5 -
Clearances to Combustible 
Materials
MANteL cLeARANceS 
Note: the combustible area above the facing must 
not protrude more than 3/4" from the facing. If it does, 
it is considered a mantel and must meet the mantel 
requirements listed in this manual. 
heARth RequIReMeNtS
The fireplace must be installed on a non-combustible hearth 
extending  a  minimum  of  12"  from  the  fireplace  opening 
(local codes may require a larger hearth). The hearth must 
also extend to both sides of the face (see the table above 
for the exact width of the face).