Monessen Hearth LX32DV User Manual

Page of 48
51D0528
11
LX Series Direct Vent Gas Fireplace
VeNtING INStALLAtIoN 
optIoNAL top VeNt AppLIcAtIoN 
The appliance is shipped as a rear vent unit. If the installa-
tion layout requires the unit to be a top vent configuration 
the appliance can be converted by the following steps.
When  removing  and  refitting  the  plates  and  adapter  be 
sure the associated gaskets are undamaged and refitted 
as required.
1.  Remove  the  eight  (8)  screws  securing  the  flue  pipe 
adapter to the fireplace body. Figure 7
2.  Set  the  flue  pipe  adapter  aside,  complete  with  the 
gasket. Do not damage the gaskets as the adapter and 
gasket must be refitted.
3.  Remove the eight (8) screws securing the flue pipe cover 
to the top of the intake box and remove the cover and 
gasket. Figure 7
W
ARNING
FP1991
remove screws
Flue Pipe 
Cover 
Flue Pipe 
Adapter 
Screws
FP1991
Figure 7 - 
Remove 16 Screws from Flue Pipe 
Adapter and Flue Pipe Cover 
4.  Remove eight (8) screws securing the flue pipe to the 
back of the intake box and remove the pipe and gasket. 
Figure 8
5.  Replace flue pipe to top of firebox. Ensure the gasket is 
in place and undamaged.  Secure with eight (8) screws. 
Figure 9
6.  Place the flue pipe cover and gasket removed in step 
3 over the flue opening in bottom of the intake box.
After conversion to top vent configuration 
the  4"  (102  mm)  flue  pipe  should  be 
concentric within the 6B\," (175 mm) outer 
collar (within 1/4").
Figure 8 - 
Remove Flue Pipe
FP1992
remove flue pipe
Screws 
Flue Cover 
Flue Pipe 
FP1992
FP1993
attach flue pipe
Figure 9 -
 Attach Flue Pipe to Top 
Vent Configurations  
Flue Pipe 
Screws
FP1993
7.  Refit the flue pipe adapter and gasket to the top of fire-
place. Secure the adapter with eight (8) screws removed 
in Step 1.