Monessen Hearth SWB400I User Manual

Page of 40
28
BLACK
TO FUSE OR
120V, 60HZ
CORDSET
GROUND
WHITE
CIRCIUT BREAKER
FAN 1
FAN 2
SPST SWITCH
FA2 FAN
JB1 JUNCTION BOX
ON SIDE OF FIREPLACE
NOTE: THE JBI JUNCTION BOX SHOULD BE INSTALLED AND ITS RECEPTACLE WIRED TO THE ELECTRICAL SYSTEM
OF THE DWELLING DURING INSTALLATION OF THE FIREPLACE ON WHICH THE FA2 FAN IS TO BE UTILIZED.
MLK36 LOUVER KIT
GAS APPLIANCE
OPENING COVER
NOTE: THE THREE PRONG RECEPTACLE
AND ITS COVER MUST BE EXPOSED AND
THE COVER PLATE MUST BE REMOVABLE
FOR INSPECTION OF WIRING CONNECTION
ONCE THE FIREPLACE IS INSTALLED.
FASTEN MODEL JBI JUNCTION
BOX TO THE SIDE OF THE 
FIREPLACE WITH THE TWO
SHEET METAL SCREWS REMOVED
FROM JUNCTION BOX
OPENING COVER.
JBI JUNCTION BOX INSTALLATION
(MLK36 LOUVER KIT MUST
BE INSTALLED IF FA2 FAN
IS TO BE UTILIZED.)
REMOVE JUNCTION
BOX COVER FROM
FIREPLACE.
G
LASS
 D
OOR
 I
NSTALLATION
 
AND
 F
AN
 A
CCESSORY
G
LASS
 D
OOR
 I
NSTALLATION
This fireplace has been tested and listed for use with Model MGD36B or MGD36PB glass doors.  For installa-
tion of the Model MGD36B or MGD36PB glass doors, see the instructions provided with the doors.
F
AN
 A
SSEMBLY
The SWB400I fireplace may be equipped with an FA2 fan IF  the fireplace is also equipped with optional
MLK36 Louver Kit.  See Figure 13. If the fireplace is to be equipped with the FA2 fan at any time, a JB1 junction
box should be installed on the fireplace during installation of the fireplace as shown by Figures 32 and 33.
Unless the JB1 junction box  is installed during the installation of the fireplace, wall finishing materials must be
removed to gain access to the side of the fireplace to install the JB1 junction box at a later date.  Complete
Installation and Operation Instructions for the FA2 Fan and MLK36 Louver Kit are included with each accessory.
NOTICE:  THE MLK36 LOUVER KIT AND A JB1 JUNCTION BOX MUST ALSO BE INSTALLED ON THE
FIREPLACE IF THE FA2 FAN IS  TO BE INSTALLED ON THE FIREPLACE.
F
IGURE
 32
F
IGURE
 33
53D9033. Rev 1 03/03