vERTICaL ThRouGh-ThE-RooF aPPLICaTIoNS 
This Gas Fireplace has been approved for,
   Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed 
within the vent system using a maximum of two 90° elbows. Figure 28
Figure 30 - 
Support Straps for Horizontal Runs
vENTING INSTaLLaTIoN 
   Up to two 45° elbows may be used within the 
horizontal  run.  For  each  45°  elbow  used  on 
the horizontal plane, the maximum horizontal 
length must be reduced by 18" (450 mm). 
Example: Maximum horizontal length 
 
No elbows   =   10’ (3 m)
 
1 x 45° elbows   =   8.5’ (2.6 m)
 
2 x 45° elbows   =   7’ (2.1 m)
   A  minimum  of  an  8'  (2.5  m)  vertical  rise  is 
required.
   Two sets of 45° elbows offsets may be used within 
the vertical sections. From 0 to a maximum of 8' 
(2.5 m) of vent pipe can be used between elbows. 
Figure 31
   The  maximum  angular  variation  allowed  in  the 
system is 270°. Figure 31
   The minimum height of the vent above the high-
est point of penetration through the roof is 2' (610 
mm). 
40' Maximum Height
8' Minimum Height 
40' Maximum Height
8' Minimum Height 
10'
Maximum 
10'
Maximum 
Support Straps
Every 3'
Support Straps
Every 3'
FP2308
1
2
3
4
1
2
3
4
FP2309
max elbow use A
Figure 31 - 
Maximum Elbow Usage 
Example: 
Elbow 1  
=   90°
 
Elbow 2  
=   45°
 
Elbow 3  
=   45°
 
Elbow 4  
=   90°
Total Angular Variation  
=   270°
FP2309