Burner FlaMe
The  flames  from  the  burner  should 
be visually checked as soon as the 
heater i
s installed and periodically during 
normal operation. In normal operation, at 
full rate, and after operating for about 15 
to 30 minutes, the flame should be yellow. 
Figure 582
If  the  flame  is  blue  and  candle-like  in 
appearance,  adjust  glass  or  add  more 
glass over ports. 
nOte:  The  type  of  installation,  vent 
system  configuration,  and  wind  effects 
may cause the flame patterns to vary.
cleanInG anD MaIntenance 
Burner, pIlOt anD cOntrOl cOMpartMent
Keep the control compartment, stones and burner areas surrounding 
the stones clean by vacuuming or brushing at least twice a year.  Make 
sure the burner porting, pilot air opening and burner air opening are free 
of obstructions at all times.
pIlOt FlaMe
The flames from the pilot should be visually checked as soon as the 
heater is installed and periodically during normal operation. the pilot 
flame must always be present when the fireplace is in operation. 
Figure 51. The pilot flame has three distinct flames, one engulfing the 
sensor, one engulfing the thermocouple, and the other reaching to the 
main burner. 
             
Burner
Inspect area around the injector. Remove any lint or foreign material 
with a brush or vacuum. 
W
arn
In
G
turn  off  gas  before  servicing  fireplace.  It  is 
recommended that a qualified service technician 
perform  these  check-ups  at  the  beginning  of 
each heating season
FP2453
hooded pilot flames
Figure 51 - 
Pilot Flame 
Thermopile 
Sensor
FP2453
FP2436
WDV flame appearance
Figure 52 - 
Burner Flame Appearance