WDV Series Gas Fireplace
FP2430
secure fireplace
6”
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use 
two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) 
screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate 
different wall thickness.
secure FIreplace to FlOOr or FraMInG 
Framing Members
Nailing Flange
FP2430
Figure 6 - 
Secure Fireplace to Framing Studs 
n
O
te 
never  install  combustible  materials  over 
front face of fireplace.
FInIshInG MaterIal
nOte: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior 
to final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating 
of Zero) may be used to cover the black painted face of the appliance. It is permissible to bring 
combustible wall board to the top of the standoffs on the top and the sides of the unit. A 300°F 
minimum adhesive may be used to attach facing materials to the black surface. If joints between 
the  finished  wall  and  the  fireplace  surround  are  sealed,  a  300°F  minimum  sealant  material 
(General Electric RTV103 or equivalent) must be used.
Nailing Flange
Nailing Flange
Screws
Screws
nOte: Fireplace may be installed on top of framing or platform constructed of combustible 
materials which do not protrude beyond the face.
Noncombustible Material