chiMNey caP iNStallatioN
Note: The proper height as previously explained is important to assure proper draft and safety. The chim-
ney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept 
in mind when determining the proper height for the chimney. The chimney should not be extended more 
than 90 inches above the supporting roof structure without additional support. In the case of an ‘A’ frame 
type construction or other steep pitch roofs that require more than 90 inches of chimney above the roof, a 
support should be attached to the chimney at the 90 inch level that is strong enough to support a wind load 
of 3Z\, pounds for each inch the chimney extends above 90 inches. The flue outlet must be a minimum of 
three feet above the point where it penetrates the roof.
cautioN: Be careful to avoid electrical shock hazard when contacting wires to the metal chimney com-
ponents.
1.  Extend the regular chimney sections until the top of the chimney is 4” below the total flue height desired. 
Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is completed.
2.  Remove the shingles from around the chimney so that the flashing may be installed, with the upper part 
of the flashing under the shingles.
3.  Set the flashing on the roof.  Hold a section of the outside pipe (13” diameter) on the flashing and scribe 
a line around the flashing, then cut the top off the flashing by cutting 1/4 inch below the scribed line. This 
should increase the diameter of the flashing outlet sufficiently to allow the flashing to be placed over the 
chimney. Figure 18
4.  Snap the last section of inlet air duct in place and slide the flashing over the chimney. Adjust the chimney 
to assure that the proper minimum clearances are maintained.
5.  Nail the flashing securely in place with eight nails.
6.  Seal the crack between the top of the flashing and the chimney with mastic. Leave some excess mastic 
at this area to be used in step eight. Note:  Use pliers and wear gloves when performing step seven to 
minimize the danger of cutting your hands on the edge of the storm collar.
7.  Place  the  storm  collar  around  the  chimney  and  put  the 
collar together like a belt in belt loops.  Slide the end of 
collar under the two loops on the other end with the loops 
facing  up.  Overlap  the  ends  of  the  collar  until  it  is  tight 
against the chimney. Bend the free end of the collar back 
over the loops to hold the storm collar securely together. 
The excess end of the storm collar may be trimmed off.
8.  Slide  the  storm  collar  down  snugly  against  the  flashing 
until  the  excess  mastic  left  in  step  six  is  forced  up  into 
the crack between the storm collar and the chimney. This 
should make the joint between the flashing and the chim-
ney watertight.
9.  Install the chimney cap by placing the cap into matching 
parts of the last chimney section. Then punch or drill 1/8 
inch  diameter  holes  in  the  inlet  air  duct  (chimney  pipe) 
where specified on the brackets and fasten it down with 
the  No.  8  screws  provided.  Do  not  penetrate  the  inner 
stainless steel pipe while installing the screws.
10.Check all the parts of the fireplace, chimney and chimney 
termination cap to assure that no parts have been dam-
aged  or  bent  during  installation  and  that  all  parts  have 
been installed properly. 
Note:  The metal used for the chimney cap has a rust pro-
tective  coating  but  the  cut  edges  of  the  parts  are  not  pro-
tected. To prevent rusting and rust staining of nearby struc-
tures, exposed parts of the chimney and chimney cap should 
be detergent washed and painted with a galvanized primer 
paint.
FP1897
scribe line 
8/08
Hold 13” Diameter 
(Outside) Pipe Vertical
Scribe Line 
at Bottom
Note: RLTCF11L chimney cap is same as RLTCF11 with 
the exception of a longer telescoping pipe which may be 
needed  for  special  installations  such  as  chase  installa-
tions.
FP1897
Figure 18
*36” 
1856O”
FP1898 
chimney cap install 
8/08 
Chimney Cap
Apply Mastic Here
Storm Collar
Flashing
* or 2’ Above Any Point Within 10’
FP1898
Figure 19