Monessen Hearth 624WBPF User Manual

Page of 32
18
624WBPF Woodburning Fireplace
53D9052
outside combustion air recommendations
  (continued)
1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air 
assembly should be avoided.  These conditions will increase the resistance to the free flow of air 
through the duct.  Refer to Figures 3 and 25 for methods of installing the outside air for combustion 
assemblies.
2. The combustion air assembly should be located at an exterior location, which is not likely to be ac-
cidentally blocked in any manner.  The assembly should be located above the snow line to prevent 
blockage by snow accumulation.
3. The combustion air inlet assembly should never be mounted in a garage or storage area where com-
bustible fumes such as gasoline might be drawn into the fireplace.
4. Combustion air can be drawn from the crawl space under a house when an adequate supply of air 
is provided by open ventilation.
5. Do not take combustion air from attic space or garage space.
Model ak-4 combustion air assembly
1.  Remove the cover plate from the 4-inch outlet opening location on the left outside of the fireplace.  
DO NOT remove the cover if the outside air will not be connected.
2.  Place the insulation ring between the AK-4 starting collar and fireplace wall and place the starting 
collar (4 inch) into the hole on the left side of the fireplace.  Fasten it in place with the four sheet 
metal screws provided.
3.  Cut  a  6-inch  diameter  opening  for  model AK-4  in  the 
outside  wall  covering  where  the  outside  vent  is  to  be 
located.
4.  Select and cut a piece of duct sufficient length to attach 
to  the  fireplace  and  protrude  at  least  three  inches  be-
yond the face of the wall to which the AK-4 inlet air vent 
will be attached. The duct may be cut with a standard 
pocket knife (use FP-4 U duct for maximum efficiency 
and safety). Do not use a combustible duct. Always use 
UL Listed Class 0 or 1 duct material.
5.  If the duct is the insulated type, push the insulation back 
from one end of the duct approximately two inches.
6.  Slip the exposed end of the duct over the starting collar 
on the fireplace.
7.  Using the sheet metal screws pro-
vided,  secure  the  duct  end  to  the 
collar attached to the fireplace.
8.  Nail  or  screw  the  combustion  air 
assembly  to  the  surface  of  the 
wall.
Note:  If the wall covering is brick or 
stone,  use  appropriate  masonry  fas-
teners. Mount the combustion air as-
sembly with “TOP’” upward to prevent 
cold air from entering through the wall. 
If it is necessary to splice the duct, a 
model  403-duct  connector  should  be 
used to splice duct sections.
outSide coMBuStioN air
FP1900
OA start collar 
8/08
Insulation Ring
Insert Shortest Side of the 
Tube through the Fireplace 
Outer Wrap to Properly 
Seal Against Firebox Wall 
and Gasket
Longer Length of the 
Tube to Outside
Figure 21
FP1900
FP1901
secure outside duct
8/08
Fireplace Outer Wrap
AK4 Combustion Air 
Kit (Shortest Toward 
Firebox)
AK4 Mounting 
Plate
Firebox Insulation 
Seal
FP1901
Figure 22