Quadra-Fire · Sapphire · 250-7233H
Female Locking Lugs
Male Locking Lugs
Step 1. 
Determine the desired location of the appliance. Check to 
ensure that wall studs or roof rafters are not in the way when 
the venting system is attached. If this is the case, you may 
want to adjust the location of the appliance.
F.  Horizontal Termination
Figure 5.4
Step 2.  
Direct vent pipe is designed with a locking connection. To 
connect the venting system to the appliance flue outlet, a 
twist-lock adapter is built into the appliance at the factory.  
Wall thickness may vary.  Remember to include wall 
thickness in minimum clearances when figuring venting 
lengths for your installation needs.
Note:  Female ends of direct vent pipe/elbows are designed 
to slide straight onto the male ends of adjacent pipes by 
orienting the  pipe indentations so they match and slide into 
the  entry slots on the male ends, see Figure 5.4.  Push 
the pipe sections completely together, then twist-lock one 
section clockwise approximately one-quarter turn, until the 
two sections are fully locked. The female locking lugs may 
not be visible from the outside. They may be located by 
examining the inside of the female ends.
Figure 5.3   
90º Elbow
Pipe Length
Pipe Length
Wall Thimble Cover
Temination Cap 
 
Wall Thimble
This is the only venting configuration that requires the 
use of the rear vent derating orifice that comes with the 
rear vent kit. NOTE: A Snorkel Kit is required.
Rear Installations for Use with Rear 
Vent Kit
Type B - 
Up & Out Installations for Top Vent 
Configurations
Type A -
 
CL
Wall Thimble Cover
Snorkel Kit
Pipe Length
Wall Strap 14 in. (356mm) Wide
Wall Thimble
21 in.
(533mm)
15-5/8 in.
(397mm)
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
•  Maintain all clearances to combustibles.
•  Do NOT allow vent to sag below connection 
point to appliance.
 •  Maintain specified slope (if required).
WARNING
Improper support may allow vent to sag or separate.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
•  Ensure vent components are locked together correctly.
•  Pipe may separate if not properly joined.