Heat & Glo  •  Everest  •  750-900  Rev. o  •  10/08
22
!
Step 4.  Positioning, Leveling, and
               Securing the Fireplace
The diagram below shows how to properly position, level, 
and secure the fi replace.
!
!
Figure 20.  Proper Positioning, Leveling, and Securing 
of a Fireplace
Figure 21.  Intermittent Pilot Ignition
NAILING TABS
(BOTH SIDES)
Step 5. The Gas Control Systems
1. Place the fi replace into position. 
2. Level the fi replace from side to side and from front to 
back.
3. Shim the fi replace with non-combustible material, such 
as sheet metal, as necessary.
4. Secure the fi replace to the framing by nailing or screw-
ing.
Intermittent Pilot Ignition (IPI) System
The gas control system used with this model is Intermittent 
Pilot Ignition (IPI).
 This system includes a 3V control valve, 
electronic module, and intermittent pilot.
WARNING:  DIRECT VENT PROPANE MODELS 
WITH IPI CONTROL SYSTEMS CANNOT BE 
USED IN CANADA.
WARNING:  CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED TO THE FIREPLACE 
JUNCTION BOX.
WARNING:  THIS UNIT IS NOT FOR USE WITH 
SOLID FUEL.