Heat & Glo • Everest • 750-900 Rev. o • 10/08
22
!
Step 4. Positioning, Leveling, and
Securing the Fireplace
Securing the Fireplace
The diagram below shows how to properly position, level,
and secure the fi replace.
and secure the fi replace.
!
!
Figure 20. Proper Positioning, Leveling, and Securing
of a Fireplace
Figure 21. Intermittent Pilot Ignition
NAILING TABS
(BOTH SIDES)
Step 5. The Gas Control Systems
1. Place the fi replace into position.
2. Level the fi replace from side to side and from front to
back.
3. Shim the fi replace with non-combustible material, such
as sheet metal, as necessary.
4. Secure the fi replace to the framing by nailing or screw-
ing.
Intermittent Pilot Ignition (IPI) System
The gas control system used with this model is Intermittent
Pilot Ignition (IPI). This system includes a 3V control valve,
electronic module, and intermittent pilot.
Pilot Ignition (IPI). This system includes a 3V control valve,
electronic module, and intermittent pilot.
WARNING: DIRECT VENT PROPANE MODELS
WITH IPI CONTROL SYSTEMS CANNOT BE
USED IN CANADA.
WITH IPI CONTROL SYSTEMS CANNOT BE
USED IN CANADA.
WARNING: CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
SOLID FUEL.