Hearth & Home Technologies CUMBGAP-PMH User Manual

Page of 36
R
Page 6
September 1, 2008
Cumberland Gap Wood Stove
7006-188E 
B
A
C1
Non-fuel 
door side
D2
Fuel Door 
side
C2
D1
CLEARANCES TO COMBUSTIBLES (UL and ULC)
G  
(Ceiling)
H
E1
E2
F1
F2
Fuel door 
side
Non-fuel 
door side
 (Ceiling)
Max Mantel Depth
10" (254mm)
(Mantel)
IF SIDE FUEL LOADING DOOR IS NOT USED: 
• Must remain in the locked position at all times
• Use clearances for non-fuel side door for both sides
TOP VENT VERTICAL
A B  
C1 C2 
D1 D2 
E1 
E2 F1 F2 G  H 
Single Wall-USA
13(330) 11.5(292)  27(686)  27(686)  18(457)  18(457) 16.5(419) 16.5(419)  20(508)  20(508)  56.5(1435)  N/A 
Single Wall-Canada 
13(330) 11.5(292)  27(686)  27(686)  18(457)  18(457)  16.5(419) 18(457)  20(508)  21.5(546) 56.5(1435)  N/A
Double Wall-USA
12(305) 10.5(267)  25(635)  26(660)  15(381)  16(406)  11(279)  16(406)  14(356)  19(483)  56.5(1435)  N/A 
Double Wall-Canada
12(305) 10.5(267)  25(635)  28(711)  15(381)  18(457)  11(279)  18(457)  14(356)  21(533)  56.5(1435)  N/A 
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP.   
(Note: Horizontal must be with 2ft (609mm) vertical 
and NOT directy off stove). 
Single Wall-USA
13.5(343) 
12(305) 
27(686) 
27(686) 
17(432) 
17(432) 
N/A 
N/A N/A N/A 
42.5(1080) 10.5(267)
Single Wall-Canada 
13.5(343) 12(305)  27(686)  28(711) 17(432)  18(457)  N/A 
N/A 
N/A 
N/A 
42.5(1080) 10.5(267)
Double Wall-USA 11(279) 
9.5(241) 
27(686) 
27(686) 
17(432) 
17(432) 
N/A 
N/A N/A N/A 39(991)
8(203)
Double Wall-Canada 
11(279) 9.5(241)  27(686)  28(711)  17(432)  18(457)  N/A 
N/A 
N/A 
N/A 
39(991)
8(203)
ALCOVE -
Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"  
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)  
Double Wall-USA 12(305) 
10.5(267) 
25(635) 
26(660) 
15(381) 
16(406) 
N/A 
N/A N/A N/A 
44(1118) 
N/A 
Double Wall-Canada 12(305) 
10.5(267) 
25(635) 28(711) 15(381) 
18(457) 
N/A  N/A 
N/A  N/A  44(1118)  N/A
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL . HORIZONTAL FLUE HEAT SHIELD, PART HTSHLD-7006, 
REQUIRED ON REAR VENT INSTALLATIONS:
Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL103 HT listed 
factory-built Class "A" chimney, or a masonry chimney.  (Mobile Home must be equipped with a spark arrestor). Additional specifications include a 
MAXIMUM 10" (254mm) MANTEL WIDTH and the following clearances.
Double Wall-USA
N/A 12(305) 
27(686) 27(686) 
17.5(445) 
17.5(445) 
N/A N/A  N/A  N/A 
39(991) 
ceiling
N/A 
Double Wall-Canada
N/A 12(305) 
27(686) 
27.5(699) 
17.5(445) 
18(457) 
N/A N/A  N/A  N/A 
39(991) 
ceiling
N/A 
USA or Canada - Single or Double Wall Pipe: 31(787) mantel
N/A 
USA or Canada - Single or Double Wall Pipe: 24(610) mantel
*
N/A 
 *
with metal shield spaced 1" (25mm) away from bottom mantel surface
HEARTH MOUNT - SIDE DOOR MUST BE LOCKED CLOSED 
Single Wall-USA 18(457) 
10(254) 
22(559) 
31(787) 
N/A 
N/A 
N/A 
N/A N/A 
N/A N/A N/A 
Single Wall-Canada 18(457) 
10(254) 
22(559) 31(787)  N/A  N/A N/A N/A  N/A  N/A 
N/A 
N/A 
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters) 
NOTE:  All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar. 
Max Depth 
 
Min Width 
 
Min Height 
Front Door 
48(1219) 
 
55(1397) 
 
72(1829) 
Side Door-USA 
48(1219) 
 
57(1448) 
 
72(1829) 
Side Door-Canada 
48(1219) 
 
61(1549) 
 
72(1829) 
NOTE: Optional Fire Screen, Part SCR-7006, can only be used in FULL Vertical
 
installations