Hearth & Home Technologies CL36D User Manual

Page of 32
02-02
21
12538 Rev D
CL36D AND CR36D INSTALLATION INSTRUCTIONS
Figure 17 - Position the Hearth Extension
18.Position the Hearth Extension
Position  and  secure  the  hearth  extension  over  the
protective metal strips that have been placed partially
under  the  fireplace  front.  These  strips  should  be
protruding approximately 2” from under the fireplace
front  and  2”  on  both  sides  of  the  fireplace  opening.
Seal the crack between the hearth extension and
fireplace with a bead of noncombustible sealant.
See  Figure  17. Apply  a  noncombustible  finishing
material of your choice to the hearth extension.
19.Finishing Material
Do not install combustible materials over the black
face of the fireplace! This poses a safety hazard and
may start a fire. You may only use noncombustible
material over the black face of the fireplace.
a. Combustible Material
Material which is made of or surfaced with wood,
compressed  paper,  plant  fibers,  plastics,  or  any
material capable of igniting and burning, whether
flame proofed or not, plastered or unplastered.
b. Noncombustible Material
Material  which  will  not  ignite  and  burn.  Such
materials  are  those  consisting  entirely  of  steel,
iron, brick, tile, concrete, slate, glass or plasters,
or any combination thereof.
20.Mantel
A  combustible  mantel  may  be  positioned  no  lower
than  41”  above  the  platform  or  floor  the  fireplace  is
set on. The combustible mantel may have a maximum
depth of 10”. See Figure 18. Combustible trim pieces
that  project  no  more  than  1½”  from  the  face  of  the
fireplace can be placed no closer than 6” from the top
and  side  of  the  fireplace  opening.  Combustible  trim
must  not  cover  the  black  metal  surfaces  of  the
fireplace. This mantel clearance is in accordance with
Section 7-3.3.3 of ANSI/NFPA211.
21.Glass Doors
This fireplace has been tested and listed for use with
doors  as  specified  in  Section  C,  “Fireplace  System
Components”.    Please  refer  to  the  manual  packed
with each set of doors for installation instructions.
c. Noncombustible Sealant Material
Sealants which will not ignite and burn; General
Electric  RTV103  Black  (or  equivalent),  Rutland,
Inc. Fireplace Mortar #63 (or equivalent).
After  completing  the  framing  and  applying  the
facing material (dry wall) over the framing, a ½”
wide  (maximum)  bead  of  noncombustible
sealant must  be  used  to  close  off  any  gaps  at
the  top  and  sides  between  the  fireplace  and
facing to prevent cold air leaks.
Only  noncombustible  materials  may  be  used  to
cover the black metal fireplace front.
Figure 18 - Mantel Position