Hearth & Home Technologies SL-750TR-E User Manual

Page of 87
Heat & Glo  •  SL-550 / 750 / 950TR-E  •  2118-900 Rev. L  •  11/08
7
B.  Tempered Glass Specifi cations
Hearth & Home Technologies appliances manufactured 
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as defi ned by the Con-
sumer Product Safety Commission (CPSC). The tempered 
glass has been tested and certifi ed to the requirements 
of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing 
Certifi cation Council SGCC# 1595 and 1597. Architectur-
al Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 
“Certifi cation and labeling requirements” 
which refers to 15 U.S. Code (USC) 2063 stating “…Such 
certifi cate shall accompany the product or shall otherwise 
be furnished to any distributor or retailer to whom the 
product is delivered.”
Some local building codes require the use of tempered 
glass with permanent marking in such locations. Glass 
meeting this requirement is available from the factory. 
Please contact your dealer or distributor to order.
This product is listed to ANSI standards for “Vented Gas 
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and 
Recreational Vehicles”, and “Gas Fired Appliances for 
Use at High Altitudes”.
A. Appliance Certifi cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance.  It should not be 
factored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced, 
these rules do not apply. Check with your local gas utility 
or authorities having jurisdiction.
When installing above 2000 feet  elevation:
•  In the USA: Reduce input rate 4% for each 1000 feet  
above 2000 feet.
•  In CANADA: Reduce input rate 10% for elevations 
between 2000 feet  and 4500 feet. Above 4500 feet, 
consult local gas utility.
Check with your local gas utility to determine proper 
orifi ce size.
NOTICE: This installation must conform with local codes. 
In the absence of local codes you must comply with the 
National Fuel Gas Code, ANSI Z223.1-latest edition in 
the U.S.A. and the CAN/CGA B149 Installation Codes in 
Canada.
Listing and Code Approvals 
 
MODELS:  SL-550TR-E, SL-750TR-E, SL-950TR-E
LABORATORY:  Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88a-2007 • CSA 2.33a-2007 
C. BTU Specifi cations
Models
U.S. (0-2000 ft.) or 
Canada (2000-4500 ft.)
Maximum 
Input 
BTU/h
Minimum 
Input 
BTU/h
Orifi ce 
Size 
(DMS)
SL-550TR-E (NG)
SL-550TR-IPI-E (NG)
U.S.
21,000
15,000
#44
Canada
18,900
13,500
#45
SL-550TRLP-E (LP)
SL-550TRLP-IPIE (LP)
U.S.
20,600
14,600
#55
Canada
18,540
13,140
#56
SL-750TR-E (NG)
SL-750TR-IPI-E (NG)
U.S.
24,300
16,900
#42
Canada
21,870
15,210
#43
SL-750TRLP-E (LP)
SL-750TRLP-IPIE (LP)
U.S.
23,400
17,600
#54
Canada
21,060
15,840
#55
SL-950TR-E (NG)
SL-950TR-IPI-E (NG)
U.S.
30,400
20,900
#37
Canada
27,360
18,810
#38
SL-950TR-E (LP)
SL-950TR-IPI-E (LP)
U.S.
30,800
23,000
#52
Canada
27,720
20,700
#53