Hearth & Home Technologies SL-750TR-E User Manual

Page of 87
Heat & Glo  •  SL-550 / 750 / 950TR-E  •  2118-900 Rev. L  •  11/08
8
E.  Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are 
those consisting entirely of steel, iron, brick, tile, concrete, 
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, 
Standard Test Method for Behavior of Materials in a 
Vertical Tube Furnace at 750 ºC 
and UL763 shall be 
considered non-combustible materials.
F.  Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa-
per, plant fi bers, plastics, or other material that can ignite 
and burn, whether fl ame proofed or not, or plastered or 
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE:  This appliance must be electrically wired and 
grounded in accordance with local codes or, in the absence 
of local codes, with 
National Electric Code ANSI/NFPA 
70-latest edition 
or the Canadian Electric Code CSA 
C22.1.
•  A 110-120 VAC circuit for this product must be protected 
with ground-fault circuit-interrupter protection, in compliance 
with the applicable electrical codes, when it is installed in 
locations such as in bathrooms or near sinks.