Hearth & Home Technologies SL-750TV-D User Manual

Page of 53
Heat & Glo  •  SL-550 / 750 / 950TV-D  •  2053-985 Rev. H  •  9/06
24
A.   Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding 
maximum horizontal dimensions of appliance mantels or 
other combustible projections above the top front edge of 
the appliance.
Finishing
B.  Facing Material
11
Figure 11.3  Noncombustible Facing Diagram
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
  Modifying or covering grilles could cause 
temperature rise and fi re hazard.
Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.
  Operation of louvers or doors.
  Access for service.
Fire Risk. 
Finish all edges and fronts to clearances and 
specifi cations listed in manual.
Figure 11.1  Clearances to Mantels or other
 Combustibles 
above 
Appliance 
1/2 INCH
(13mm) 
12 INCHES
(305mm)
TOP FRONT EDGE
OF FIREPLACE
12 INCHES
(305mm)
NON-COMBUSTIBLE
MATERIAL ONLY
SIDE SEAL
JOINT 
1/2 INCH
(13mm)
1/2 INCH
(13mm)
FINISH WALL MATERIAL
MAY BE COMBUSTIBLE
- TOP AND SIDES
TOP SEAL
JOINT
•  Black metal appliance front may be covered with non-
combustible material only.
•  Do NOT overlap combustible materials onto appliance 
front.
•  Install combustible materials up to specifi ed clearances 
on top front and side edges.
•  Seal joints between the fi nished wall and appliance top 
and sides using only a 300º F minimum sealant.
WARNING
WARNING