Hearth & Home Technologies SL-750TV-D User Manual

Page of 53
Heat & Glo  •  SL-550 / 750 / 950TV-D  •  2053-985 Rev. H  •  9/06
8
D.  Inspect Appliance and Components
C.  Tools and Supplies Needed
Before beginning the installation be sure that the following 
tools and building supplies are available.
Reciprocating saw 
 Framing material
Pliers 
 Hi temp caulking material
Hammer  
Gloves
Phillips screwdriver 
 Framing square
Flat blade screwdriver   Electric drill and bits (1/4 in.)
Plumb line 
 Safety glasses
Level Tape 
measure 
Manometer Voltmeter
Non-corrosive leak check solution
1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
One 1/4 inch female connection (for optional fan).
Inspect appliance and components for 
damage. Damaged parts may impair safe 
operation.
•  Do NOT install damaged components.
•  Do NOT install incomplete components.
•  Do NOT install substitute components.
Report suspected damaged parts to dealer.
•  Carefully remove the appliance and components from 
the packaging. 
•  The vent system components and trim doors are shipped 
in separate packages. 
•  The gas logs may be  packaged separately and must be 
fi eld installed. 
•  Report to your dealer any parts damaged in shipment, 
particularly the condition of the glass. 
Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be voided 
by, the following actions:
•  Installation and use of any damaged appliance or vent 
system component.
• Modifi cation of the appliance or vent system.
•  Installation other than as instructed by Hearth & Home 
Technologies.
•  Improper positioning of the gas logs or the glass door.
•  Installation and/or use of any component part not 
approved by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
Figure 2.2  Typical Vertical Installation
The following B-vent components are needed for installa-
tion (see Figure 2.2).
• Fireplace Box
• Pipe Components
• Firestops
•  Attic Insulation Shield
• Elbows
• Strapping
•  Roof Flashing or Chase Top
• Termination Cap
• Storm Collar
•  Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the 
installation to ensure maximum safety and benefi t. 
VERTICAL TERMINATION CAP
STORM COLLAR
ATTIC INSULATION SHIELD
GAS B-VENT
PIPE SECTION (S)
FIRESTOP SPACER
ROOF FLASHING
OR CHASE TOP
WARNING