Hearth & Home Technologies 8300 User Manual

Page of 43
HearthStone Quality Home Heating Products Inc
                                                                   Champlain 
Model #8300
 
 
24
 
Cet appareil peut être installé dans un 
maison préfabriquée (mobile) déjà installée 
à demeure si les règlements locaux le 
permettent. 
Cet appareil doit être utilisé uniquement 
avec les types de gas indiqués sur la plaque 
signalétique.  Ne pas l’utiliser avec d’autres 
gas sauf si un kitde conversion certifié est 
installé.
E
LECTRICAL 
C
ONNECTIONS
 
 
NOTE:  OPEN VALVE DOOR ON THE FRONT FOR ELECTRICAL AND GAS 
CONNECTIONS. 
 
T
HERMOSTAT
 
The ON/OFF/T-STAT switch or wall 
mounted thermostat controls the Champlain.  
We recommend installation of the 
thermostat for more comfortable 
performance, however you may still 
override the thermostat by setting the switch 
to “ON”. The thermostat controls the unit by 
“calling for heat.” The thermostat turns the 
unit on when the room is cold, and turns the 
unit off once the room is warmed 
sufficiently. The thermostat is controlled by 
a 750 millivolt DC two-wire circuit. 
 
 
R
EMOTE 
C
ONTROL
 
There are two different optional remote 
controls. Both of the remote controls are 
capable of turning the unit on and off. One 
of the optional remotes also allows you to 
control the temperature of the stove, (in the 
same way the thermostat controls the 
heater), from anywhere in the vicinity of the 
unit. If “ON” & “OFF” are the only controls 
required, Kit #90-56912 can be used. If you 
would like to control the temperature via the 
remote control, use Kit #90-56914. 
Installation instructions are provided with 
the kits. 
 
T
HERMOSTAT 
P
LACEMENT
 
The thermostat should be placed in the same 
room or living space as the unit. Typically 
5’ (1.5m) off the floor and away from any 
influences that may cause the temperature in 
the vicinity of the thermostat to be 
unrepresentative of the room temperature in 
general. Such influences might include 
strong lighting, a heater vent from the 
central heating system, or a nearby drafty 
window. 
 
Placement of the thermostat on an inside 
wall rather than an outside wall is 
preferable. Do not place the thermostat 
directly behind or too close to the unit, 
otherwise heat from the unit will 
immediately satisfy the thermostat and turn 
the unit off. 
 
T
HERMOSTAT 
W
IRING
 
The thermostat wire from the unit to the 
thermostat can be surface mounted, routed 
under the  floor, or through walls, etc. The 
thermostat should be connected to the unit 
using a maximum of 40’ (12m) of insulated 
thermostat wire (minimum of 18 Ga.) When 
making these connections, position the 
Conditionally approved for purchased mobile 
home installation. This appliance 
may be 
installed in an aftermarket permanently located, 
manufactured (mobile) home, where prohibited 
by local codes. 
This appliance is only for use with the type of 
gas indicated on the rating plate.  This appliance 
is not convertible for use with other gases, unless 
a certified kit is used, available through your 
local HearthStone dealer.