Hearth & Home Technologies 5100-I User Manual

Page of 24
5100-I  WOOD INSERT
Page 14
January 30, 2004
R
250-1960  Rev B
BLOWER REPLACEMENT INSTRUCTIONS
Part 832-1991 for Serial Numbers 131586 and below
Part 832-3190 for Serial Numbers 131587 and above
Figure 14A
NOTE:  When the speed control is turned clockwise, it will click on to high speed.  Continue to turn the speed control 
clockwise to decrease the speed.  At full clockwise, the blower should blow gently, but should not stop.
1.  With the unit plugged in, turn the Speed Control Knob to slow.  (Full clockwise.)
2.  Use a small screwdriver to adjust the fan speed by turning the adjustment mechanism through the hole on the 
side of the Speed Control. 
3.  Adjust the speed so the fan runs slowly but does not stop.  Turn clockwise to slow the fan and counterclockwise 
to increase the speed. 
FAN SPEED CONTROL ADJUSTMENT, IF NECESSARY*
*The fan Speed Control for this unit is adjusted at the factory, and normally does not require further 
adjustment.
Remove 2 Spring Handles
TOOLS NEEDED:  #2 PHILLIPS SCREWDRIVER
1)   Unplug blower cord from outlet.
2)   Pull insert out from the fireplace.
3)   Remove the 2 Air Control spring handles.
4)   Remove the lower grill by removing 2 screws in the center of 
the grill.
5)   Unplug the snap disc by-pass switch and speed control from 
the wiring harness for easier access to blower. (Located on 
right hand side of stove as you face the unit).
6)   Remove screws from blower frame on side of insert.
7)   Blower will then slide out through side of insert.
8)   Install new blower in same fashion.
9)   Re-connect snap disc & speed control to wiring harness and 
replace screws in blower frame.
10)  Re-install lower grill, replace screws & spring handles.
11)  Push insert back into the fireplace.
12)  Plug blower cord back into outlet. 
LEFT FAN
AUX POWER 
       LEFT
RIGHT FAN
POWER IN
SPEED 
CONTROL
SNAP DISC 
BY-PASS SWITCH
SNAP DISC
Small Red Female
Small Red Female
Small Red Female
Small Red Female
Large Blue Male
Large Blue Male
Large Red Female
Large Red Female
Large Red Female
Large Red Female
Large Blue Male
Large Blue Female 
Large Blue Female
Large Blue Female
Figure 14B
WIRING DIAGRAM