5100-I  WOOD INSERT
R
250-1960  Rev B
 AIR QUALITY AND YOUR QUADRA-FIRE INSERT 
In recent years there has been an increasing concern about the quality of our air.  Much of the blame for poor air quality has 
been placed on the burning of wood for home heating.  In order to improve this situation we at Quadra-Fire have developed 
cleaner burning inserts that surpass the stringent requirements for emissions established by our governing agencies.  Your 
4100-I, like any other appliance, must be properly operated in order to ensure that they perform the way they are designed 
to perform.  Improper operation and maintenance may cause any wood burning unit to release more particulate, adversely 
affecting the environment.  
The story of the Three Burning Stages . . .
It helps to know a little about the actual burn process, which entails three discernible burning stages.  The first stage is called 
the kindling stage. During this stage the fuel reaches the boiling temperature of water, 212°F, evaporating the moisture 
found to some degree in all wood. 
 
Because the process takes heat from the insert during this initial drying stage, each new load of wood reduces the chances 
for a good, clean burn.  For this reason it is always best to burn dry, seasoned firewood, and operate the controls properly.  
The bottom control on the right side of your insert is called the Start-Up Air Control and is used primarily during this first 
kindling stage of burning. 
During the secondary stage, the wood gives off flammable gases which burn above the fuel with bright flames.  These 
flames above the fuel must be maintained until the third stage to ensure proper burning.  During this stage you may adjust 
your insert for a low burn rate.  To achieve a low burn rate it is necessary to close down the air while still maintaining some 
flames.  If the flames tend to go out, the setting is too low.  The Primary Control will assist you in adjusting the insert for a 
low burn rate.
The third stage of burning is the charcoal stage.  This happens when the flammable gases have been burned and the 
charcoal remains.  The coals burning with hot blue flames is a naturally clean portion of the burn.  It is very important to 
reload your insert while enough lively hot coals remain in order to provide the amount of heat needed to dry and rekindle 
the next load of wood.  Open up both controls for a short while before reloading to liven up the coal bed.  You should also 
break up any large chunks and distribute the coals so the new wood is laid on hot coals.  Leave both controls open until 
the new wood load is burning well enough to maintain the secondary stage of burning and then set controls to your desired 
heat output setting.  
START-UP AIR SYSTEM
The combustion air enters at the rear of the firebox through the rear air tubes.  This air supply is controlled by the Start-Up 
Air Control. See Figure 19A.
PRIMARY AIR SYSTEM
The primary air enters at the upper front of the firebox near the top of the glass door.  This preheated air supplies the neces-
sary fresh oxygen to mix with the unburned gases, helping to create secondary, tertiary and quaternary combustion.  This 
air is regulated by the Primary Air Control.  For more primary air (more heat), push rod in.  For less primary air (less heat), 
pull rod out.  See Figure 19A.
In other words . . .
Pulling either control towards you closes off the air available to the insert in that area. Pushing either control opens it, allow-
ing air circulation to the area.  A good analogy to remember for this procedure is the gas pedal on your car.  Pushing in the 
gas pedal makes the engine run faster.  Letting off (pulling the control back) makes the car run slower.  
Primary Air Control
Start-Up Air Control
Figure 19A
OPEN - PUSH IN
CLOSE - PULL OUT