Enviro C-11290 User Manual

Page of 48
Initial Installation
QUALIFIED INSTALLERS ONLY
h
oRizontaL
 i
nstaLLation
:
1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the 
way when the venting system is attached. If this is the case, you may want to adjust the location of 
Sealant
Female 
Locking 
Lugs
Male 
Locking 
Lugs
Figure 25: Twist-Lock Connection
Woodscrews
Wall Thimble
Strap
Sheet metal 
screws
Fold strap 
here
1
1
/
4
(3.2cm)
Figure 27: Installing Decorative Wall Thimble.
10"
(254mm)
10"
(254mm)
Figure 26: Wall Framing Hole for 
Horizontal Installation. 
the appliance.
2. Direct  vent  pipe  and fittings  are  designed with  special  twist-lock 
connections. Assemble the desired combination of black pipe and 
elbows to the appliance adapter with pipe seams oriented towards 
the wall or floor, as much out of view as possible.
  Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe 
(non-flared end). Place a bead of high temperature silicone on the 
male  edge  of  the  outer  pipe.  Push  the  pipe  sections  completely 
together,  then  twist-lock  one  section  clockwise  approximately  ¼ 
turn,  until  the  two  sections  are  fully  locked.  The  female  locking 
lugs will not be visible from the outside, on black pipe. They may 
be located by examining the inside of the female ends as shown in 
Figure 25.
Notes: 
(a) Twist-lock procedure: four (4) indentations, located on the female 
end  of  the  pipes  and  fittings,  are  designed  to  slide  straight  onto  the 
male  ends  of  adjacent  pipes  and  fittings,  by  orienting  the  four  pipe 
indentations so they match and slide into the four entry slots on the 
male end.
(b) Horizontal runs of vent pipe must be supported every 36” (915mm). 
Wall straps are available for this purpose, also when running horizontal 
pipe  minimum  clearances  to  combustibles  must  be  maintained; 
2”  (51mm)  at  top,  1½”  (38mm)  at  sides,  1½”  (38mm)  at 
bottom.
3.
 With the pipe attached to the stove in the correct location, mark the 
wall for a 10” (25.4cm) x 10” (25.4 cm) square hole (refer to Figure 
26). The center of the square hole should match the center line of 
the horizontal pipe. Cut and frame the 10” (25.4cm) x 10” (25.4cm) 
hole in the exterior wall where the vent will be terminated. Refer to 
20
Figure  18.  If  the  wall  being 
penetrated  is  constructed  of 
non-combustible material i.e. 
masonry  or  concrete,  a  7” 
(17.8cm) hole is acceptable.
4.  Position  the  horizontal  vent 
termination  in  the  center 
of  the  10”  (25.4cm)  x  10” 
(25.4cm)  hole,  and  attach 
to  the  exterior  wall  with 
the  four  screws  provided. 
Before  attaching  the  vent 
termination  to  the  exterior