Secondary Installation
QUALIFIED INSTALLERS ONLY
O
PTIONAL
 F
AN
 K
IT
 I
NSTALLATION
:
If the Haven is installed the burner and valve assemblies must be removed. If the Haven is not installed 
the fan can be installed through an access hole at the lower rear of the unit.
CAUTION:  When  servicing  controls,  label  all  wires  prior  to  disconnection.  Wiring  errors  can  cause 
improper and dangerous operation. Verify proper operation after servicing.
Kit Contents:
This  kit  includes  a  fan  assembly,  a  wiring  harness,    a  temperature  sensor,  fan  control  dial,  two  (2) 
grommets, and two (2) 8-32 x 3⁄4”  bolts.
Please ensure that your fan kit has not been damaged. If so, contact your dealer, distributor, or courier 
company before starting this installation.
O
PTIONAL
 F
AN
 K
IT
 I
NSTALLATION
 T
HROUGH
 B
ACK
 
OF
 H
AVEN
:
1. Use a flat head screwdriver or a 1⁄4” socket to remove the six (6) screws holding the back cover on 
(see Figure 44).
2. Remove the two (2) bottom screws holding the stand-off on (see Figure 45) and swing it out of the 
way.
Figure 43.  Wiring Diagram For Fan Control.
The  optional  fan  is  thermostatically  controlled 
and  it  will  not  operate  if  the  appliance  is  cold. 
A few minutes after the appliance is lit and the 
variable speed control is set at a desired setting, 
the  fan  will  automatically  turn  on.  The  fan  will 
automatically  turn  off  a  few  minutes  after  the 
appliance is shut off.
The fireplace must be electrically connected and 
grounded  in  accordance  with  local  codes  or,  in 
the absence of local codes, with the current CSA 
C22.1  Canadian  Electrical  Code  Part  1,  Safety 
Standards  For  Electrical  Installations,  or  The 
National Electrical Code ANSI / NFPA 70 in the 
US.
WARNING: The electrical grounding instructions 
must  be  followed.  The  fan  should  be    properly 
grounded.
Fan Control
Black
Black
Black
Long
Black
Short
Black
Electrical
Power Cord
White
White
Green
120
o
F (49
o
C)
Temperature
Sensor
Figure 44: Removing Back Plate From Haven.
3. Install the two (2) grommets; place a 8-32 x 3⁄4”  
bolt through each grommet then attach the bolt 
to the back cover using a 1⁄4” socket. 
4. Ensure the wiring harness is attached to the fan 
then hook the two (2) slots on the fan box over 
the grommets installed in the last step.
5.  Slide  the  fan  with  the  wiring  harness  attached 
into the hole in the back of the haven, motor side 
first (see Figure 46).
30