Enviro Haven Direct Vent Fireplace User Manual

Page of 41
31
Figure 48. Install Fan Control 
Box.
Figure 49. Install Fan Control Nut.
Secondary Installation
6. Re-install the screws for the back cover and the stand-off.
7. Remove the two (2) screws holding the control panel in place. Pull the panel out of the way.
8. Slide the snap switch in place under the holding tabs above the SIT valve (see Figure 47). 
9. Remove knob and nut from the fan controller. Place the dial stud through the fan hole in the control 
board through the back to the front (see Figure 48). Tighten the nut on the front side to keep the fan 
controls in place (see Figure 49), then install the knob onto the stud. 
10.  Use  marrettes  to  connect  the  fan  wiring  harness  wires  to  the  house  wiring  when  the  Haven  is 
installed.
11. Re-install the control panel.
Figure 45: Move Back Stand-
Off.
Figure 46: Installing Fan 
Through the Back.
Figure 47: Installing Temperature 
Sensor.
O
PTIONAL
 F
AN
 K
IT
 I
NSTALLATION
 T
HROUGH
 F
RONT
 
OF
 H
AVEN
:
1. Ensure the appliance is turned off and cool.
2. Remove the fascia, glass door (see M
AINTENANCE
 A
ND
 S
ERVICE
 - G
LASS
 D
OOR
 R
EMOVAL
), logset, embers 
and firebox liner.
3. Remove the  two (2) screws holding the control panel in place. Pull the panel out of the way.
Figure 50. Remove the pilot shield, orifice and valve assembly.
4. To  remove  the  burner  undo 
the  wing  nut  under  the  right 
side of the burner (see Figure 
8) and remove the screw. Lift 
the  right  end  of  the  burner 
up,  slide  it  to  the  left  (off  of 
the main orifice), then up and 
out.
5. Remove  the  pilot  shield, 
orifice  and  valve  assembly 
(see Figures 50).