the  cap  assembly.  It  is  important  that  the 
vent pipe extend into the vent cap a sufficient 
distance  with  a  minimum  of  11⁄4”  (3.2  cm) 
overlap.  Secure  the  connection  between  the 
vent  cap  pipe  and  the  vent  cap  by  attaching 
the  two  sheet  metal  straps  extending  from 
the  vent  cap  assembly  into  the  outer  wall  of 
the vent pipe. Use the two sheet metal screws 
provided  to  connect  the  straps  to  the  vent 
pipe. Bend any remaining portion of the sheet 
metal straps back towards the vent cap, so the 
decorative wall thimble will conceal it (see left 
image in Figure 23).
STEP 7. Slide the decorative wall thimble up to the wall 
surface and attach with the screws provided. 
Apply  decorative  brass  or  chrome  trim  if 
desired (see right image in Figure 23). 
NOTES:  
(1) 
The four wood screws provided should be replaced 
with  the  appropriate  fasteners  for  stucco,  brick, 
concrete, or other types of siding.
(2)  For  buildings  with  vinyl  siding,  a  vinyl  siding 
standoff, should be installed between the vent cap 
and  the  exterior  wall  (see  Figure  24).  Attach  the 
vinyl siding standoff to the horizontal termination. 
The  vinyl  siding  standoff  prevents  excessive  heat 
from  possibly  melting  the  vinyl  siding  material. 
Note that the horizontal vent termination bolts onto 
the flat portion of the vinyl siding standoff (shaded 
area in Figure 24), so that an air space will exist 
between the wall and the vent termination.
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 24: Installing Vent Cap with Vinyl Siding 
Stand-Off.
Figure 25: Installing Horizontal Vent Termination.
STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 
10” (25.4 cm) square hole (refer to Figure 22). The center of the square hole should match the 
center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the 
exterior wall where the vent will be terminated. Refer to Figure 15. If the wall being penetrated 
is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole 
is acceptable.
STEP 4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm) 
hole, and attach to the exterior wall with the four screws provided. Before attaching the vent 
termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to 
make a seal between the termination and the wall. The arrow on the vent termination should be 
pointing up, insure that the proper clearances to combustible materials are maintained.
STEP 5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black 
decorative wall thimble cover over the vent pipe.
STEP 6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into 
20