Operating Instructions
For Your Safety, Read Safety Precautions And 
Lighting Instructions Before Operating
E)   Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season, 
or  for  servicing,  turn  the  gas  shut  off  valve  to 
OFF.  DO NOT FORCE IT. If the unit is going to 
be serviced, turn off the electrical power to the 
unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, 
for the first two to four hours. This will cure the paint, logs, gasket material, and other products used 
in the manufacturing process. It is advised that a door or window be opened as the unit will start to 
smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, 
including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good 
gas fireplace glass cleaner, available at your local Enviro dealer. See “M
AINTENANCE
 A
ND
 S
ERVICE
; G
LASS
 
D
OOR
 R
EMOVAL
” and “M
AINTENANCE
 A
ND
 S
ERVICE
; C
LEANING
 T
HE
 G
LASS
.”
B
LOWER
 
SPEED
 (O
PTIONAL
):
��
���
��
Figure 5.  Control Panel
Figure 6. Fan Control
����� �������
������
����
���
�������
B
URNER
 L
IGHTING
:
A)  Make sure the pilot is lit.
B)  Turn gas control knob COUNTER CLOCKWISE to ON.
C)  Flip the burner switch to ON.
D)  Turn HI/LO knob to the desired flame height.
The  blower  will  come  on  only  when  the  fireplace  is  up  to  temperature 
(approximately 20 minutes). The speed of the fan can be changed by turning the 
fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE 
until it “clicks” off (Figure 6). 
It is advisable not to operate the blower below 
1
/
3
 speed as it puts a strain on 
the windings of the blower and running the blower at lower speeds could also 
cause premature fan failure.
N
ORMAL
 S
OUNDS
 D
URING
 O
PERATION
:
Table 1: Normal Sounds
Component
Sound & Reason
DV36 & Fascia
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor
Clinking when it senses to turn the blower on or off.
Pilot Flame
Quiet whisper while the pilot flame in on.
Blower / Fan
Air movement that increase and decreases with the speed of the blower. The 
blower is pushing the heat from the fireplace into the room.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.