Enviro EG40 BV User Manual

Page of 23
Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENTING
:
This model must have a vent opening in the rear of the unit.  Confirm this and also check that the label on the right 
side panel door states “Vented Room Heater”.
WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the 
room.  The draft hood located in the same atmospheric pressure zone as the combustion air inlet to the appliance.  
It is also designed to draw room air for proper heat circulation from the rear of the unit.  Blocking or modifying the 
louvers in any way can create hazardous situations, either through poor venting or by overheating. It is important 
that this unit has sufficient air circulation for proper venting and combustion thus provisions must be made for the 
supply of adequate combustion and ventilation air.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system or 
tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.
THE APPLIANCE CANNOT BE CONNECTED TO A CHIMNEY FLUE SERVICING 
A SEPARATE SOLID FUEL BURNING APPLIANCE.
F
LUE
 G
AS
 S
PILL
 S
WITCH
:
NOTE: This heater must be properly connected to a venting system.  This heater is equipped with a vent safety 
shutoff system designed to protect against improper venting of combustion products.  This safety switch is located 
on the rear of the appliance close to the drafthood relief opening.
If  the  switch  trips  more  than  once,  the  chimney  should  be  inspected  by  a  qualified  service 
technician for possible blockage or severe down draught conditions.
M
ANUFACTURER
S
 G
ENERAL
 V
ENTING
 G
UIDELINES
:
This information is compiled by the manufacturer as a very general rule for single appliance venting of the EG40 gas 
stove with 4 inch Type B gas vent. Refer to the Venting manufacturer’s directions for installation.
Venting  code  and  regulations  may  vary  from  area  to  area,  please  check  with  the  local,  state/provincial  codes 
regarding the suitability of your application.
For other special venting requirements, please refer to the local, state/provincial or national codes.
The venting system should be assembled and installed according to the vent manufacturer’s instructions and the 
local, state/provincial or national codes. 
G
ENERAL
 V
ENTING
 F
OR
 T
HE
 EG40:
This stove should be vented by certified 4” (10 cm) Type B Gas Vent or a flexible gas vent liner that may be encased 
in 6” (15 cm) decorative stove pipe. The flue collar of the appliance will fit inside of standard vent and may be 
fastened directly to the vent.
The ENVIRO incorporates its own internal draft hood, so no additional external draft hood is required.
Check periodically that the vent is unrestricted and an adequate draught is present when the unit is in operation.