Initial Installation
QUALIFIED INSTALLERS ONLY
E
LECTRICAL
 R
EQUIREMENTS
:
The ENVIRO EG40 will operate without electrical power. This model has a millivolt gas control, which uses the pilot 
flame to generate enough electricity to operate the main burners. The appliance is equipped with a blower and must 
be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the 
current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, 
OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the U.S.
��
��
��
��
��
��
��
����������
���
�����
����
����
������
��� ����������
�����
�����
�����
����� ������
�����
�����
�����
����
���
������
�����
�����
������
������ ��� �
�������� ����������
�����
�����
����� ������
�����������
������
������� ������ �� �����
��� ����
���������
��� ������
���������
������
WARNING:  Electrical  grounding  instructions.  This 
appliance  is  equipped  with  a  three-prong  (grounding) 
plug for your protection against shock hazard, and must 
be plugged directly into a properly grounded three-prong 
outlet.  
DO  NOT  cut  or  remove  the  grounding  prong  from  this 
plug.
CAUTION:  Label  all  wires  prior  to  disconnection  when 
servicing  controls.  Wiring  errors  can  cause  improper 
and  dangerous  operation.  Verify  proper  operation  after 
servicing.
NOTE:
• Operation of the fan increases the efficiency and the heat 
output of the appliance.
• The thermostat connects to the two purple wires in the 
harness
• Control panel light uses a 7 Watt max. bulb
• If the unit is installed in a Mobile Home it must be 
connected to a grounding rod.
• If the unit is installed in a Mobile Home it must be 
bolted securely to the floor.
Figure 6: EG40 BV Wiring Diagram.
Wire Size
Max. Length
14 gauge
100 ft  (30.48 m)
16 gauge
60 ft   (18.29 m)
18 gauge
40 ft   (12.00 m)
20 gauge
25 ft   (7.62 m)
22 gauge
18 ft   (5.49 m)
COOL / HEAT
PROGRAM
DOWN
UP
70 ° F
70 ° F
ON
OF
F
Figure 7: Wiring of a Thermostat
Table 2.  Recommended Thermostat 
Wire Size.